SATURATED STEAM GASIFIER

Minimum Clearance
The Uniconfort Modular Gasification system recommends a minimum of 1.5 metres clearance from all system extremities, including minimum of 1.5 metres clearance above the boiler.

Boiler Noise Level
The level of A-weighted equivalent continuous acoustic pressure at the operator’s work position (in front of the boiler) is lower than 70 dB. The measurement was taken at 1 meter from the boiler and 1.60 metres from floor height.

Regular Maintenance Regular maintenance of the boiler increases its working life and operating safety. All the maintenance tasks on the boiler must be carried out when the machine is switched off and with the power supply disconnected and locked out.

Price: 


Regular maintenance periods are reported below:

Unit to be checked Frequency Operations
Reduction gears and flow adjusters Every 30 days Top up with suitable oil
Rotating parts that are subject to normal wear and tear Every 30 days Check and grease with suitable grease
Cast-iron grate of hearth Every 30 days Check and replace any worn cast iron parts
Combustion-air fans Every 30 days Check and clean
Electrical parts and components of the main power panel Every 30 days Clean with compressed air.

Maintenance (Daily/Weekly)
• General cleanliness
• Visual inspections:
      General
      Hydraulic systems
      Pressure levels
      Fuel feeding systems
      Water levels of back fire prevention systems
      Vacuum level of boiler
      Alarm system function

Annual Maintenance Service
• Fuel storage inspection and cleaning
      Basic cleaning
      Conveyors/Augers
      Boiler and its combustion chamber/masonry cleaning
      Grate and its mechanism
      Hydraulic system
      Lubrication: blower and conveyor bearings
      Back-fire prevention system testing
      Safety valve operation, boiler water level sensors
      Flue gas blower belts
      Electric connections

Equipment & Service Warranty
• Two Year Complete Parts Warranty
• Ten Year Major Component Warranty
• 1 Week Commissioning Effort